FEATURES
AVERAGE RATED LED LAMP LIFE OF 50,000 HOURS AT L70 IN TA40C ENVIRONMENTS.
DURABLE ALUMINIUM OR STAINLESS STEEL BODY OPTIONS.
HIGH PERFORMANCE OPTICS WITH IMPROVED ILLUMINATION UNIFORMITY.
UV RESISTANT MOULDED LENS WITH INTEGRAL IP66 SILICONE SEAL.
SUITS STANDARD DIAMETER 34MM POLES AND SPIGOT BRACKETS.
LOW PROFILE IP66 PROTECTION, IK10
AMBIENT TEMPERATURE, -25°C TO 40°C
APPLICATIONS
DESIGNED FOR THE SAFE ILLUMINATION OF INFRASTRUCTURE SUCH AS CONVEYORS, WALKWAYS AND PLATFORMS ON MINES, POWER STATIONS, WHARVES, SUGAR MILLS, EYE WASH STATIONS AND GENERAL INDUSTRIAL PLANTS.
CERTIFICATE CERTIFICATE NO.
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
CE BCTC-150911282
CE BCTC-150911283
IP66 BCTC-150911284
ETL 150801588SHA-002
PRODUCTS QUICK INFORMATION VERSION DIM (MM) INSTALLATION PIPE DIA (MM) MASS (KG)
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
FREELANDER 48W 382×184×204 Φ34 4.9
FREELANDER LED FREELANDER HPS
SPECIFICATION LIST | FREELANDER |
POWER | 48W |
NOMINAL VOLTAGE | AC100-240V |
POWER FACTOR | >0.95 |
PCB CONNECTION | 12 SERIES 16 PARALLELS |
DRIVER OUTPUT | 30-48V/1.2A |
CHIPS | EPISTAR 5630 |
PCB QUANTITY | 6PC |
CHIP QUANTITY | 192PCS |
CCT | 3000-6000K |
CRI | >80 |
LUMINOUS FLUX | 3998LM |
EFFICIENCT | 87LM/W |
BEAM ANGLE | 120° |
BODY MATERIAL | ALUMINIUM |
DIFFUSER MATERIAL | PMMA |
IP RATE | IP66 |
AMBIENT TEMPERTURE | -25°C TO 50°C |
STORAGE TEMPERATURE | -25°C TO 50°C |
INNER BOX | 430×235×210 |
OUTER BOX | 435×705×430 |
PACKING INFORMATION
1. EGG GRATE 2. 430×235×210 BOX 3. 435×705×430 BOX
* 430×235×210 BOX CAN FIT 1PC FREELANDER
* 435×705×430 BOX CAN FIT 6PCS FREELANDERS
INSTALLATION OR ASSEMBLY INSTRUCTIONS
INSTALLATION OR ASSEMBLY INSTRUCTIONS
PLEASE READ THESE INSTALLATION INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR MAINTAINING THIS EQUIPMENT. THESE INSTRUCTIONS AND LOCAL REGULATIONS(WHERe APPLICABLE), BY AN AUTHORISED AND LICENCED ELECTRICIAN.
importANT – THE PRODUCT MUST BE MAINTAINED AND OPERATED IN ACCORDANCE WITH THE MANUFACTURE’S
INSTRUCTIONS, FAILURE TO DO SO MAY DAMAGE THE PRODUCT AND SERVICES. IT IS STRonGLY RECOMMENDED THAT THIS importANT NOTE BE COMMUNICATED TO THE OWNER AND OR OPERATOR OF THE INSTALLATION AT THE TIME OF SITE COMMISSIONING. GOOD PRACTICE DOES NOT RECOMMEND THE 24/7 USE OF PRODUCTS WITHOUT THE APPLICATION OF SUITABLE SWITCH CYCLE INTERVALS. PNQ IS NOT RESPonSIBLE FOR ANY PRODUCT NOT MAINTAINED IN ACCORDANCE WITH THE RECOMMENDED PROCEDURES. ALL PRODUCTS SHOULD BE THOROUGHLY CLEANED ON A REGULAR BASIS TO ENSURE THE OPTICAL PERFORMANCE, TOGETHER WITH THE ELECTRICAL,MECHANICAL AND STRUCTURAL INTEGRITY AS DESIGNED, IS MAINTAINED THROUGHOUT THE SERVICE LIFE OF THE PRODUCT. “ConSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR”
1. PRODUCT SPECIFICATION:
SPECIFICATION LIST | FREELANDER |
IP RATE | IP66 |
NOMINAL VOLTAGE | AC100-240V |
LINE CURRENT | 1.2A |
SUITABLE FOR DIRECT MOUNTING ON FLAMMABLE SURFACES | NO |
2. STORAGE: PRIOR TO INSTALLATION PRODUCTS ARE TO BE STORED IN COOL AND DRY CONDITIONS.
3. APPLICATION: THE INSTALLATION APPLICATION AND ORIENTATION OF THE PRODUCT IS DESIGNED IN ACCORDANCE WITH THE NOMINATED PRODUCT IP RATING, CLASS DESIGNATION AND THESE INSTALLATIONS. INSTALLATION ENVIRonMENTS OUTSIDE THESE ConDITIONS ARE NOT RECOMMENDED.
4. INSTALLATION: INSTALLATION OF THE PRODUCT IS TO BE COMPLETED BY AN AUTHORIZED AND LICENCED ELECTRICIAN, IN ACCORDANCE WITH THESE INSTRUCTIONS, RELEVANT AUSTRALIA STANDARDS AND LOCAL REGULATIONS (WHERe APPLICABLE). FOR ELECTRonIC ConTROL EQUIPMENT (WHEN SUPPLIED) DO NOT MEGGER BETWEEN A AND N. ALL CABLE TERMINATIONS MUST BE INSTALLED IN ACCORDANCE WITH THE DESIGNATED IP RATING OF THE PRODUCT. EXTERIOR PRODUCTS (WHERe RELEVANT), INSTALLED IN HIGH WIND ENVIRonMENTS MUST HAVE SUITABLE INSTALLATION / FASTENING METHODS APPLIED TO ENSURE THE PRODUCT’S MOUNTING POINTS ARE NOT DAMAGED THROUGH, CORROSION, ConSTANT VIBRATION AND OR MOVEMENT. EXTERIOR PRODUCTS ARE DESIGNED WITH PRECISE VERTICAL AIMING LIMITS, WHICH SHOULD NOT BE EXCEEDED
5. LAMPS: THE PRODUCT IS DESIGNED WITH THE SUPPLIED (LEDS) / LAMP/S AND IT IS STRonGLY RECOMMENDED THAT ANY LAMP /(LEDS) CHANGES (IF ANY) BE MADE IN ACCORDANCE WITH THE TYPE, COLOUR AND BRAND SUPPLIED. PIERLITE AUSTRALIA IS NOT RESPonSIBLE FOR THE PRODUCT PERFORMANCE OF ALTERNATIVE LAMP/S USED.
6. MAINTENANCE: THE SUPPLY MUST BE ISOLATED BEFORE OPENING OR ACCESSING THE LUMINAIRE. PRODUCT MAINTENANCE IS importANT AND IS CRITICAL TO THE PRODUCTS DESIGNED PERFORMANCE. THE PRODUCT IS TO BE MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS. P&Q IS NOT RESPonSIBLE FOR ANY PRODUCT NOT MAINTAINED IN ACCORDANCE WITH THE RECOMMENDED PROCEDURE OR INTERVALS. FOR RECOMMENDED LAMP / LED MAINTENANCE GUIDES, PLEASE REFER TO THE LAMP INSTALLATION GUIDELINES SUPPLIED WITH THE LAMP PRODUCT OR THE NOMINATED LAMP MANUFACTURER’S WEBSITE. FOR PRODUCTS SUPPLIED WITH GLASS VISORS OR COVERS, DO NOT OPERATE THE PRODUCT WITH A DAMAGED VISOR OR COVER; IT IS RECOMMENDED THE PRODUCT BE TURNED OFF, AREA SURROUNDING THE PRODUCT VACATED AND THE DAMAGED GLASS REPLACED BY A PROFESSIonAL INSTALLER IMMEDIATELY.
7. ELECTRICAL SUPPLIES: ALWAYS ENSURE THE CORRECT SUPPLY VOLTAGE IS AS THE RATING LABEL ON THE PRODUCT. SLIGHT VARIATIONS OF THE NOMINAL LINE VOLTAGE WITHIN THE RANGE OF +6%/-6% ARE EXPECTED, ALTHOUGH LUMINAIRES SHOULD NOT BE OPERATED ConTINUOUSLY AT MORE THAN +6%/-10% OF THE RATED SUPPLY VOLTAGE OF THE CONTROL GEAR OR TAPPING.