FESTURES
UNIQUE DESIGN USING MODULAR LED SOURCE KIT WITH HIGH EFFICIENCY LED CHIPS.
RANGE OF LUMEN PACKAGES AND LIGHT DISTRIBUTIONS.
INTEGRAL DRIVER WITH AUTOMATIC TEMPERATURE ConTROLLER TO PREVENT OVER HEATING IN HIGH AMBIENT ENVIRONMENTS.
LOW PROFILE DESIGN REDUCES WIND RESISTANCE AND MAXIMISES HEAT DISSIPATION FOR OPTIMUM PERFORMANCE.
DIE-CAST, LOW COPPER ALUMINIUM HOUSING WITH POLYESTER POWDERCOAT FINISH, RESISTANT TO CORROSION AND SALINE ENVIRONMENTS.
INSTALLATION FEATURES INCLUDE SAFETY CUT-OFF SWITCH, IP66 RAPID ELECTRICAL CONNECTOR, CLASS II ELECTRICAL CLASSIFICATION ONLY.
ConTROL OPTIONS, DIMMING, MIDNIGHT FUNCTION AVAILABLE.
APPLICATIONS
HIGHWAY, URBAN ROAD, PAVEMENT
CERTIFICATE CERTIFICATE NO.
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
CE BCTC-2011009558-SZJR
CE BCTC-2011009559-SZJR
IP65 BCTC-2011009792-SZJR
PRODUCTS VERSION DIM (MM) INSTALLATION PIPE DIA (MM) MASS (KG)
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
LINCOLN 80W LED 572×320×126 Φ76MM 3.5
LINCOLN 160W LED 705×320×126 Φ76MM 5.0
LINCOLN 240W LED 837×320×126 Φ76MM 6.5
LINCOLN 320W LED 970×320×126 Φ76MM 8.0
MODULE SOURCE LINCOLN 1
LINCOLN 2 LINCOLN 3 LINCOLN 4
SPECIFICATION LIST | LINCOLN 1 | LINCOLN 2 | LINCOLN 3 | LINCOLN 4 |
POWER | 80W | 160W | 240W | 320W |
NOMINAL VOLTAGE | AC100-240V | AC100-240V | AC100-240V | AC100-240V |
POWER FACTOR | >0.95 | >0.95 | >0.95 | >0.95 |
PCB CONNECTION | 4 PARALLELS | 8 PARALLELS | 12 PARALLELS | 16 PARALLELS |
CHIPS | COB 20W | COB 20W | COB 20W | COB 20W |
MODULE QUANTITY | 1PC | 2PC | 3PC | 4PCS |
CHIP QUANTITY | 4PCS | 8PCS | 12PCS | 16PCS |
CCT | 3000-6000K | 3000-6000K | 3000-6000K | 3000-6000K |
CRI | >80 | >80 | >80 | >80 |
LUMINOUS FLUX | 6800LM | 13600LM | 20400LM | 27200LM |
EFFICIENCT | 85LM/W | 85LM/W | 85LM/W | 85LM/W |
BEAM ANGLE | 120° | 120° | 120° | 120° |
BODY MATERIAL | ALUMINIUM | ALUMINIUM | ALUMINIUM | ALUMINIUM |
DIFFUSER MATERIAL | TEMPERED GLASS | TEMPERED GLASS | TEMPERED GLASS | TEMPERED GLASS |
IP RATE | IP65 | IP65 | IP65 | IP65 |
INSTALLATION PIPE DIAMETER | Φ76MM | Φ76MM | Φ76MM | Φ76MM |
INSTALLATION HEIGHT | 6-8M | 9-11M | 9-11M | 9-11M |
AMBIENT TEMPERTURE | -30°C TO 50°C | -30°C TO 50°C | -30°C TO 50°C | -30°C TO 50°C |
STORAGE TEMPERATURE | -30°C TO 50°C | -30°C TO 50°C | -30°C TO 50°C | -30°C TO 50°C |
PACKING CARTON | 597×355×130 | 730×355×130 | 862×355×130 | 995×355×130 |
PACKING INFORMATION
1. FOAM FILLED COVER 2. FOAM FILLED COVER BOTTOM
3. LINCOLN 1: 597×355×130MM CARTON LINCOLN 2: 730×355×130MM CARTON
LINCOLN 3: 862×355×130MM CARTON LINCOLN4 : 995×355×130MM CARTON
INSTALLATION OR ASSEMBLY INSTRUCTIONS
PLEASE READ THESE INSTALLATION INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR MAINTAINING THIS
EQUIPMENT. THESE INSTRUCTIONS AND LOCAL REGULATIONS(WHERe APPLICABLE), BY AN AUTHORISED AND LICENCED ELECTRICIAN.
importANT – THE PRODUCT MUST BE MAINTAINED AND OPERATED IN ACCORDANCE WITH THE MANUFACTURE’S INSTRUCTIONS, FAILURE TO DO SO MAY DAMAGE THE PRODUCT AND SERVICES. IT IS STRonGLY RECOMMENDED THAT THIS importANT NOTE BE COMMUNICATED TO THE OWNER AND OR OPERATOR OF THE INSTALLATION AT THE TIME OF SITE COMMISSIONING. GOOD PRACTICE DOES NOT RECOMMEND THE 24/7 USE OF PRODUCTS WITHOUT THE APPLICATION OF SUITABLE SWITCH CYCLE INTERVALS. P&Q IS NOT RESPonSIBLE FOR ANY PRODUCT NOT MAINTAINED IN ACCORDANCE WITH THE RECOMMENDED PROCEDURES. ALL PRODUCTS SHOULD BE THOROUGHLY CLEANED ON A REGULAR BASIS TO ENSURE THE OPTICAL PERFORMANCE, TOGETHER WITH THE ELECTRICAL,MECHANICAL AND STRUCTURAL INTEGRITY AS DESIGNED, IS MAINTAINED THROUGHOUT THE SERVICE LIFE OF THE PRODUCT.
“ConSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR”
1. PRODUCT SPECIFICATION:
| LINCOLN 1 | LINCOLN 2 | LINCOLN 3 | LINCOLN 4 |
IP RATE | IP65 | IP65 | IP65 | IP65 |
NOMINAL VOLTAGE | AC100-240V | AC100-240V | AC100-240V | AC100-240V |
2. STORAGE: PRIOR TO INSTALLATION PRODUCTS ARE TO BE STORED IN COOL AND DRY CONDITIONS.
3. INSTALLATION DRAWINGS
4. ELECTRICAL FAULT FINDING AND RELACEMENT:
THE SUPPLY MUST BE ISOLATED BEFORE OPENING THE LUMINAIRE. IF ALL ConNECTIONS ARE VERIFIED TO BE CORRECT, THE PRODUCTS ENVIRonMENT MAY BE HAVINg AN ADVERSE EFFECT TO THE COMPONENTS. IF THIS IS THE CASE PLEASE ConTACT YOUR SUPPLIER FOR A MORE SUITABLE REPLACEMENT. ANY FAULT FINDING